Fire risk assessment for blocks of flats
Most purpose-built blocks need a Type 1. Here is when they need more.
- Written report to keep on file
- Clear action plan, highest risk first
- Price agreed before booking
In a block of flats the assessment covers the parts residents share: entrance hall, stairs, corridors, bin and meter cupboards, plant rooms and the way onto the roof. Since the Fire Safety Act 2021 it also takes in the structure, the external walls and the front doors of the flats, because those are what keep a fire inside the flat where it started.

Type 1 to Type 4
The four types come from the guide Fire safety in purpose-built blocks of flats, published on gov.uk. In short:
Type 1 looks at the common parts and opens nothing up. The assessor still checks a sample of flat front doors from the corridor side. The guide says a Type 1 will normally be enough for most purpose-built blocks.
Type 2 covers the same common parts but with some destructive checks, for example lifting a ceiling tile or taking off a riser panel to see if the walls carry on up to the slab. It is asked for when there is a real doubt about the fire separation, and someone usually has to make good afterwards.
Type 3 adds a look inside a sample of flats, still opening nothing. Type 4 is the same with destructive checks in the flats as well. Both go further than the Order requires, so they are kept for specific worries, such as a block where flats have been altered and nobody has a record of how.
A made-up example
A five-storey block from the 1970s, thirty flats, one stair. On a Type 1 walk the assessor notes:
- Ground floor meter cupboard. Door held shut with a bungee cord, no lock, cables going up into the ceiling void.
- Fourth floor. Two flat front doors with letter plates and no closer on one of them.
- Bin store door wedged open with a brick.
Those cables into the ceiling void are a good reason to talk about a Type 2 on that floor. The front door findings go to the freeholder, because flat front doors in a block fall under the Order.
What the 2022 regulations added
The Fire Safety (England) Regulations 2022 apply to buildings with two or more sets of flats. All of them must give residents fire safety instructions and information about fire doors. Above 11 metres, communal fire doors must be checked every three months and flat front doors once a year, on a best endeavours basis. Blocks of 18 metres or more, or with seven or more storeys, have further duties, including a secure information box and floor signs.
The assessor will tell you which of these apply. Checking the doors themselves is a fire door inspection, which is a separate service.
Tell us what the building is used for, the postcode and roughly how big it is. You get a written price back.